- There are no more items in your cart
- Shipping Calculated at checkout
-
Sub-Total (inc. VAT)
£0.00
Prepare bare dry wall and unsealed bare plaster prior to the application of Thermoguard fire upgrade systems. 1,400+ colour options. Overcoatable with Thermoguard Safewalls and Wallcoat systems to achieve BS EN Class B and old Class O.
- 1,400+ colours available from RAL, BS, NCS and Thermoguard Select with LRV
- Can be used as part of a system to achieve 30 or 60 minute Fire Resistance on internal walls and ceilings (requires specification and additional coats)
- Also suitable for use on bare plaster or drywall before Safewalls Onecoat Flame Retardant and Safeceilings Onecoat Ultra Matt as part of a system
- Sold in 50m² and 125m² pack sizes to aid correct application
- Please Note: This product is suitable as a primer only and does not provide fire or anti-microbial resistance
Please note should you be unsure whether this product/system is suitable for your requirements please see below.
Product customisation
Don't forget to save your customization to be able to add to cartPlease note should you be unsure whether this product/system is suitable for your requirements please download and complete the 'Thermoguard Wall/Ceiling Enquiry Form' and return by email to [email protected]
Upon receipt our team will respond within 24-48 hours with specification/advice on our best suggestion for your project. If you have any questions regarding this process consult our technical department on 0113 2455450 (option 2).
Thermoguard Safewalls Drywall Plaster Primer is a water-based emulsion used to prepare bare dry wall and unsealed bare plaster on walls and ceilings prior to the application of fire upgrade systems. Overcoatable with Thermoguard Safewalls and Wallcoat systems to achieve BS EN Class B and old Class O.
1,400+ colours available to choose from in RAL, BS and NCS ranges. Also available Thermoguard Select shades with LRV (Light Reflectance Values).
Can be used as part of a system to achieve 30 or 60 minute Fire Resistance on internal walls and ceilings (requires specification and additional coats). The finished system provides a smooth aesthetically pleasing matt finishes for internal ceilings. Finished system provides a smooth aesthetically pleasing matt or eggshell finish (depending on system components).
Also suitable for use on bare plaster or drywall before Safewalls Onecoat Flame Retardant and Safeceilings Onecoat Ultra Matt as part of a system.
Please Note: This product is suitable as a primer only and does not provide fire or anti-microbial resistance.
Quick Links - Click To Jump To Section:
- Features & Benefits
- LRV Explained
- Application
- Preparation & Application
- Application Conditions
- Quality Assurance
- Environmental, Health & Safety
Features & Benefits
- For bare drywall or plaster walls or ceilings
- 1,400+ colours available from RAL, BS, NCS and Thermoguard Select with LRV
- Can be used as part of a system to achieve 30 or 60 minute Fire Resistance on internal walls and ceilings (requires specification and additional coats)
- Also suitable for use on bare plaster or drywall before Safewalls Onecoat Flame Retardant and Safeceilings Onecoat Ultra Matt as part of a system
- Sold in 50m² and 125m² pack sizes to aid correct application
- In normal conditions product will be touch dry in an hour and fully dry after 4 hours
- Low VOC EU limit for this product (cat A/i) is 140g/l. This product contains 16g/lv
- Generally just 1 coat is required
- Water-based and eco-friendly
- Please Note: This product is suitable as a primer only and does not provide fire or anti-microbial resistance
LRV Explained
What is LRV?
Light Reflectance Value is the acronym referring to the lightness and darkness of colours, running on a scale from 0% to 100% that increases with the light in a colour.
LRV is commonly confused with "intensity", which actually refers to how vivid or dull a colour is.
Why is LRV important?
LRV is vital for contractors and designers working with care homes, hospitals and other healthcare facilities used by patients suffering from colour blindness, visual impairments or dementia. Using colours that are distinct from another will help aid navigation and can improve mood.
Using clear and high level contrasting colours will help patients distinguish between walls and ceilings, seating, doors and other surfaces. The best way to measure contrast is with the LRV, with at least 30 point difference between colours on adjoining surfaces, helping meet legal requirements of the Equality Act 2010.
Application
- 1 good coat applied at 10-12.5m² per litre
Preparation & Application
- Surfaces to be clean dry and firmly adhering
- Ensure good ventilation
- Do not apply while condensation could occur during drying
- Apply using a woven short pile roller sleeve or synthetic brush
- Spray:
- Thin 5% water OR Airless Graco 1500, 3500 or equivalent
- 3/8” line, 30 mesh filter on machine, no filter in gun
- 521, 523, 621 or 623 tip
- Ensure coverage is applied as per can i.e., 50m² can covers 50m²
See Data Sheets for detailed Application information.
Application Conditions
- Do not apply in temperatures under 8°C or above 30°C
- Conditions Maximum relative Humidity below 75%
- Surface should be at least 3°C above the dew point
Drying Times
- In normal conditions product will be touch dry in an hour and fully dry after 4 hours
Quality Assurance
Thermoguard products are manufactured under ISO 9000.
Environmental, Health & Safety
Water-based low odour, low VoC, user and eco-friendly. Please see the Safety Data Sheet above before use.
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Thermoguard
- Interior / Exterior Use
- Interior Use
- Water / Solvent Based
- Water
- For Use On
- Drywall
Plaster - Single, Two or Three Pack
- Single
- Interior/Exterior Use
- Interior
- Application
- Brush, Roller, Spray
- Coverage
- Supplied in pre-measured packs to apply 1 coat to 50m² or 125m²
- Colour(s)
- White
- Colour(s)
- Fully Tintable
- Suitable For Use On
- Bare Drywall
- Suitable For Use On
- Bare Plaster
- Finish
- Matt
- Application Method
- Brush
- Application Method
- Roller
- Application Method
- Spray
- Product Usage Type
- Primer
- Product Range
- Safewalls
- Colour Family
- Brown
- Colour Family
- Pink
- Colour Family
- Orange
- Colour Family
- Purple
- Colour Family
- Yellow
- Colour Family
- Black
- Colour Family
- White
- Colour Family
- Neutral
- Colour Family
- Dark
- Colour Family
- Lilac
- Colour Family
- Salmon
- Colour Family
- Beige
- Colour Family
- Grey
- Colour Family
- Green
- Colour Family
- Blue
- Colour Family
- Red
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Thermoguard Safewalls Drywall Plaster Primer is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
General Painting Application Kit
Provides the basics for any painting project. Whether it is a one off job, or you just want to make sure the right application tools get to site. Provides an economical way of making sure you will have what you need Ideal for interior and exterior paint projects, including uPVC surfaces, walls, ceilings, and more. Click to jump down to...
Thermoguard Safewalls Onecoat Anti-Viral Smoke & Flame Retardant
Anti-viral fire protection for painted walls in a single coat, with 4000+ matt and satin colour options including LRV. Kills Coronavirus, Flu and bacteria fast. Safewall’s highly concentrated mix of safe, encapsulated nano-particle biocidal metals damage the shells of human coronaviruses and flu and the membranes of bacteria, so their death...
Thermoguard Safeceilings Onecoat Ultra Matt
Flame Retardant Intumescent protection in one coat for painted or new primed ceilings, in 1,400+ matt and LRV colours. Durability and infection control are much less needed on ceilings and areas free from wear and tear. Decorative fire upgrade and finish in one coat Protects ceilings to BS EN Class B & Class O Please Note: Onecoat...