Follow us on:

Thermoguard Fire Varnish Overcoat (Interior)

TFVOI
THE8781

For use in combination with and over Thermoguard Fire Varnish Basecoat in internal applications - available in clear and a choice of woodstain colours.

  • For timber/timber derived substrates
  • Clear, UV and wear-resistant finish
  • Certificate of Supply available when used over Thermoguard Fire Varnish Basecoat

Important!

Product customisation

Don't forget to save your customization to be able to add to cart
  • 250 char. max
Colour Group
Size
Finish
£77.28(incl. VAT)
£64.40(ex. VAT)
Quantity
Please choose your colour
In Stock and Available for Delivery (See Delivery Options Below)

Description

Please note should you be unsure whether this product/system is suitable for your requirements please download and complete the 'Thermoguard Wood Enquiry Form' and return by email to [email protected]

Upon receipt our team will respond within 24-48 hours with specification/advice on our best suggestion for your project. If you have any questions regarding this process consult our technical department on 0113 2455450 (option 2).

Intended Use – Clear Fire Protection Overcoat for Fire Varnish System for Interior Wood

Thermoguard Fire Varnish Overcoat (Interior)

Thermoguard Fire Varnish is a varnish system with the option of a clear or stained finish for the Fire Protection of timber and timber derived substrates to BS Class 1 and Class 0 Surface Spread of Flame as well as BS EN Class B s2 d0 (for 30 or 60 minutes Fire Resistance see Thermoguard Fire Varnish 30 & 60 Minute System). The special formula provides a tough, durable finish to internal and external wood. Clear or stained overcoats enhance the natural beauty of the wood while fire protecting new/bare surfaces. Thermoguard Fire Varnish Overcoat (Interior) and Thermoguard Fire Varnish Overcoat (Exterior) provide protection against UV and wear.

The Thermoguard Fire Varnish System is made up of Thermoguard Fire Varnish Basecoat (a two component, water based product consisting of a base and activator mixed together before use - see image above) which is a clear, intumescent varnish to be finished with Thermoguard Fire Varnish Overcoat (Interior) or Thermoguard Fire Varnish Overcoat (Exterior) available in a clear or stained matt or satin finish (a gloss finish is available in batch quantities for large projects if required). Thermoguard Fire Varnish Overcoats provide protection against UV and wear whilst Thermoguard Fire Varnish Basecoat provides the Fire Protection.

Transparent Wood Stains

Representations shown below; represented as solid colours in the colour picker further above.

Intumescent Fire Protection

When exposed to fire, the Thermoguard Fire Varnish System expands to create an insulating barrier, protecting timber surfaces from flames, heat and oxygen and suppressing emission of deadly smoke & gasses.

Specification and Application

To BS Class 1 and Class 0 Surface Spread of Flame as well as BS EN Class B s2 d0 (for 30 or 60 minutes Fire Resistance see Thermoguard Fire Varnish 30 & 60 Minute System)

Prepare and apply – (INTERIOR)

  • 1 coat of Thermoguard Fire Varnish Basecoat
  • 1>4 days after Basecoat is dry, apply 1 coat of Thermoguard Fire Varnish Overcoat (Interior) Matt or Satin Clear or 2 coats of Thermoguard Fire Varnish Overcoat (Interior) Matt or Satin Woodstain Colour.

Prepare and apply – (EXTERIOR, DAMP, HIGH WEAR AREAS or FRUITWOODS)

  • 1 coat of Thermoguard Fire Varnish Basecoat
  • 1>4 days after Basecoat is dry, apply 2 coats of Thermoguard Fire Varnish Overcoat (Exterior) Matt or Satin Clear or Woodstain Colour.

Please note: Timber must be clean and thoroughly dry prior to application (maximum 18% moisture content). Any gaps should be sealed with Thermoguard Intumescent Mastic. Fire should be prevented from accessing unprotected wood surfaces and for external applications it is recommended wood has been sealed on the reverse face to stop water ingress.

NOT suitable for the topside of floor surfaces that will be trafficked/walked on.

A gloss finish is available in batch quantities for large projects, contact us for details.

Available Pack Sizes

Application by painters, decorators & other professional users only. Refer to instructions on Fire Varnish Base & Overcoat containers.

Previously Varnished and Stained Surfaces or Wood Preservers

The Thermoguard Fire Varnish System can be applied over firmly adhered standard clear varnish. For existing stained varnishes, stain coatings, old fire coatings or if in doubt, contact our Technical Department on 0113 2455450.

  • If preservatives are required, use rapid drying clear non waterrepellent grades*.
  • For tanalised or other preservative treatments, contact our Technical Department.

*Allow adequate time for stain or preservative fluids to escape before applying the Thermoguard Fire Varnish System.

Fire Test Standards and Certification

  • BS EN Class B s2 d0
  • Class 1 and Class 0

Note - For 30 or 60 mins Fire Resistance see Thermoguard Fire Varnish 30 & 60 Minute System.

For fire protection to doors, see Door Upgrade Products

Thermoguard will issue a Certificate of Supply upon request for each correctly specified project for Insurance, Fire and Building Control Authority and Client Records against proof of purchase. After successful application of a complete system a certificate can be applied for HERE

Preparation

  • Cover, countersink & fill, or use non-ferrous, galvanized, stainless or sheradised fittings
  • Ensure surfaces are dry, clean and free of all contamination.
  • Varnished, sealed or non-porous wood should be abraded thoroughly with medium grade silicone carbide abrasive when dry to provide a good key.

Application to OSB/Sterling Board

This is a board made of chips of wood glued together to form a hard non-decorative board. If it needs fire coating, Thermoguard Fire Varnish or Thermoguard Timbercoat BS Class 1/0 & EN Class B System can be applied to it. However we first recommend a test is carried out by applying a small amount of the proposed coating to the board to check for "cessing" / "cissing" (where coating gathers together in lumps and may leaving bare patches between). If this occurs the board should be degreased/cleaned and allowed to dry before testing again - if this still does not provide a satisfactory application please contact our Technical Team for further advice on 0113 2455450 (option 2) or send a message to [email protected].

Conditions

During application & drying of the full system:-

  • Ensure surfaces are thoroughly dry – max 18% moisture content.
  • Maximum relative humidity RH 75%.
  • Ensure adequate ventilation.
  • Minimum air temperature 6°C. Minimum surface temperature 3°C above dewpoint – avoid condensation.

NEW Fire Regulations and Tests Explained

  • The new fire standard BS EN test lasts 20 mins. with airflow replaces the old BS 476 tests which lasted 10 mins and restricted airflow.
  • The new standard for flamespread and heat release Class B replaces Class 0.

The new BS EN tests also monitor -

  • Smoke & Gas “s” – s1 + s2 are none or very low & compliant, s3 moderate smoke, s4 = heavy smoke.
  • Flaming Droplets or Airborne particulates – d0 is none, d1 = low, d2 = moderate, d3 = high levels.



IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.



Product Details
8781-968144

Data sheet

For Use By
Professional Use
Interior / Exterior Use
Interior Use
Single, Two or Three Pack
Single
Application
Brush, Roller, Spray
Coverage
Supplied in pre-measured packs to apply 1 coat to 20m²
Touch Dry
8 Hours
Suitable For Use On
Wood
Finish
Satin
Finish
Matt
Product Usage Type
Varnish
Product Range
Fire Varnish
Fastest Delivery
Next Working Day
Colour Family
Oak
Colour Family
Walnut
Colour Family
Rosewood
Colour Family
Clear
Colour Family
Mahogany
Colour Family
Pine
Colour Family
Ebony
Colour Family
Grey
Colour Family
Teak
Colour Family
White
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


questions chris on 2022-10-25 16:49:34
Question: 

Can you confirm if Thermoguard Fire Varnish Overcoat (Interior) coloured - can this be overcoated on HR prof 1 coat,

Answer from Rawlins’ Technical Team: 

No, this is designed to be used in conjunction with Thermoguard Fire Varnish Basecoat and should not be over painted.


Question about the product

* Required fields
(read)
Send

IMPORTANT SHIPPING & DELIVERY INFORMATION

Thermoguard Fire Varnish Overcoat (Interior) is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT


You might also like
Thermoguard Fire Varnish Basecoat

Thermoguard Fire Varnish Basecoat

A clear intumescent varnish that is the first coat of a 2 coat system (3 coats externally) for the decorative Fire Protection of timber and timber derived substrates to BS Class 1, Class 0 and EN Class B s2 d0. See Thermoguard Fire Varnish Overcoat (Interior) or Thermoguard Fire Varnish Overcoat (Exterior) to complete the system. Complete...

Price £154.56 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery
General Painting...

General Painting Application Kit

Provides the basics for any painting project. Whether it is a one off job, or you just want to make sure the right application tools get to site. Provides an economical way of making sure you will have what you need Ideal for interior and exterior paint projects, including uPVC surfaces, walls, ceilings, and more. Click to jump down to...

Price £12.08 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery
Thermoguard Timbercoat BS...

Thermoguard Timbercoat BS Class 1/0 & EN Class B System

4,000+ coloured fire retardant paint system for interior and exterior timber surfaces.  Each pack contains the correct amount of basecoat (Thermoguard Timbercoat Insulating Basecoat) and topcoat (Smoke & Flame Retardant Dualcoat) to ensure protection is achieved in line with the manufacturers recommendations to the area in question....

Price £222.18 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery
Thermoguard Fire Varnish BS...

Thermoguard Fire Varnish BS Class 1/0 & EN Class B System

A clear fire retardant varnish for interior and exterior timber surfaces. Important! For use on timber with a minimum thickness of 9mm. Woodstains are only available on the following shipping options: Express: 1-3 Working Days Delivery (Thermoguard DS) Economy: 7-10 Working Days Nationwide Delivery See further below for...

Price £231.84 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery
Thermoguard Fire Varnish 30...

Thermoguard Fire Varnish 30 & 60 Minute System

A clear intumescent varnish (with 9 woodstain shades available) for interior and exterior timber surfaces. Each pack contains the correct amount of basecoat (Fire Varnish Basecoat) and topcoat (Thermoguard Fire Varnish Overcoat (Interior) or Thermoguard Fire Varnish Overcoat (Exterior)) to ensure protection is achieved inline with the...

Price £231.84 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery
Thermoguard Fire Varnish...

Thermoguard Fire Varnish Overcoat (Exterior)

A clear/wood stain-coloured decorative lacquer for use over Thermoguard Fire Varnish Basecoat for exterior surfaces. Each 20m2 pack of Thermoguard Fire Varnish Exterior Overcoat is sufficient to apply the required 2 coats to 20m2 of surface area. Important! Restricted to professional users. Not for sale to, or use by the general...

Price £154.56 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery