Sika Parex Tecgrip V

660277
SIK9662

2-component, polyester based, anchor grout for bolt to hole diametric differences up to 25mm.

  • For temperatures 5℃ to 25℃ (Winter) and 10℃ to 35℃ (Summer)*
  • Used for the fixing of steel bolts and bars into pre-drilled holes within concrete, rock, brickwork, stonework, masonry, etc.
  • 7-day compressive strength: ~95MPa

*Please note: Summer Grade is available subject to an extended lead time - please contact our Technical Department for availability on 0113 2455450 (option 2) or send a message to [email protected]

Size
Option
£64.61(incl. VAT)
£53.84(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

Description

Tecgrip V, part of the Tecgrip range of polyester resin anchor grouts, is used for the fixing of steel bolts and bars into pre- drilled holes within concrete, rock, brickwork, stonework, masonry or other substrates capable of supporting the required load. Formed anchors are high strength fixings which are resistant to corrosion and may be loaded quickly after installation. Placed anchors are resistant to vibration, do not exert expansive forces and may be designed for under water installation.

Tecgrip V consists of a low viscosity polyester resin plus a catalysed filler. The two components are mixed to produce a filled resin grout, which may be poured or pumped into suitably prepared anchor holes. The mixed grout is coloured dark grey and is used for downward facing holes where the hole diameter is up to 25mm greater than the bolt or bar diameter.



Quick Links - Click To Jump To Section:




Features & Benefits


  • Uses include:
    • Base plates
    • Rail tracks
    • Starter bars and dowels
    • Safety fences and balustrades
    • Reciprocating machinery
    • High impact loads



Typical Anchor Properties @ 20°C


Anchor Strengths

Length of Anchor Bond (mm) Uniaxial Pull Out Load (tonnes)
100 3
200 8
400 16
600 24

 

Deformed bar to BS 4449 in unreinforced 20N/mm² concrete, holes drilled by rotary percussive method on air flush.

 

Parameters controlling Uniaxial Pull Out Load:

  • Type and strength of base material
  • Length of resin anchor bond
  • Hole forming or drilling method
  • Type of fixing, bolt or bar

 

Safety Factors:

  • Non critical applications : 1.5 minimum
  • Critical applications : 2.0 minimum
  • Compliance with relevant codes of practice and standards



Working Time


Working Time
Winter Grade 8 - 12 minutes (above 20°C setting will be rapid)
Summer Grade 18 - 22 minutes (below 10°C setting will be extended)

 

Compressive strength

Age At Test 2 Hours 1 Day 7 Days
Compressive Strength (N/mm2) 40 80 95

 

  • Tensile Strength: 17N/mm2 @ 7 Days
  • Compressive Modulus: 16kN/mm2 @ 7 Days
  • Density: 1800kg/m3

 

Standards

Tecgrip V has been tested in accordance with the appropriate parts of BS 6319, BS 5080.



Anchor Installation


Holes and Bar Types

Holes should be drilled using rotary percussive drills with air or water flush. The drill bit should be of the integral type with an elliptical head. Holes which are diamond cored should be under-reamed or roughened. Holes which are drilled with a rotary percussive non-flushing drill bit should be cleaned using a steel rotary brush. Loosened dust should be blown out of the hole using compressed air through an extension tube reaching to the bottom of the hole. Cast holes should taper so that the hole diameter is smaller at the mouth than the bottom.

Steel bars used for anchoring should be deformed such as those manufactured to BS 4449. Threaded bars may be used. When using smooth bars an extra safety factor should be incorporated into the anchor design.



Grout and Bar Placing


Place contents of resin can into plastic container or pail. Slowly add catalysed filler whilst mixing. Continue mixing until a uniform colour is achieved. Correct mix proportioning must be used to achieve the designed anchor strength. Pour mixed grout into prepared holes, rodding if necessary to ensure grout flows to the bottom of the hole. Once grout has been placed insert bar into hole and gently twist and press home to the required depth. The bar should be left undisturbed until the grout has hardened.

Equipment should be cleaned with Solvent prior to grout hardening.

For installations under water, consult our technical team on 0113 2455450 (option 2) or send a message to [email protected].



Precautions


Temperature in Use

Tecgrip Products may be placed at temperatures between 5°C and 35°C. Use in structural situations at temperatures above 60°C is not recommended. Consult our technical team on 0113 2455450 (option 2) or send a message to [email protected] for further advice.

Tecgrip V Resin and Solvent are flammable. Should fire occur extinguish with CO2 or foam.



Grout Volumes Required


The following table gives typical Tecgrip V grout volumes required for given bolt/bar and hole diameters. The volumes given are in cm3 per 100mm of bond length.

Hole Dia. Bolt (mm) Dia. Bolt (mm) Dia. Bolt (mm) Dia. Bolt (mm) Dia. Bolt (mm)
16 10        
20 20 12      
25   35 25    
32     50 30  
40       75 50
48         100



Product Details
9662-966505

Data sheet

Manufacturer
Sika
For Use By
Professional Use
Interior / Exterior Use
Exterior Use
Single, Two or Three Pack
Two-Pack
Pack Size
4.415KG
Pack Size
4.415kg
Size
4.415kg
UN Number
UN1866 (A)
Manufacturer
Sika
Components
2K
Usages
Concrete Repair
Product Usage Type
Resin Grout
Product Range
Parex
Categorised As
Repairs > Low Temperature Grouts
Seasonal
Cold Weather
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


Be the first to ask a question about this product!


Question about the product

* Required fields
(read)
Send

IMPORTANT SHIPPING & DELIVERY INFORMATION

Sika Parex Tecgrip V is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT