Follow us on:

Sika Parex Tecfast Concrete

Sika Parex Tecfast Concrete

629545
SIK9665

1-component, rapid setting, deep fill, EN 1504-3 Class R4 repair concrete. Typical applications include the installation of road furniture, barriers and stanchion posts, backfilling manhole frames, recasting of pit-blocks and concrete elements.

  • Allows 'return to service' in only 1 hour
  • Layer thickness 20-650mm
  • 7-day compressive strength: ~95MPa
  • 2-hour compressive strength ~22MPa

Size
£39.08(incl. VAT)
£32.57(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

questions 1 question about the product
Description

Tecfast Concrete is a single pre-mixed Portland cement based non-shrink concrete designed with selected graded silica aggregates and additives. The mixed product may be placed in sections of 20mm up to 650mm in a single pour.

Tecfast Concrete is suitable for all concrete works where early strength development is required in order to allow early use of the placed sections. The product may be used for localised repairs plus large area placement or re-instatement of concrete pavements.

The mixed concrete, when placed, will harden in approximately 20 minutes. The compressive strength gain will reach 22N/mm2 within 2 hours allowing early opening of sections to foot and vehicular traffic.

The self-contained product only needs to be mixed with water on site. The product is chloride free and can be safely used in contact with steel reinforcement. After placement no special curing is required in moderate ambient conditions. In rapid drying conditions, expected rain or frost protection should be applied.



Quick Links - Click To Jump To Section:




Features & Benefits


  • Non-flammable - Fire Class A1
  • The volume yield of each 25kg bag of Tecfast Concrete is approximately 11.5 litres
  • Suitable for the following repair methods as defined in BS EN 1504:
    • 3.2 – Concrete restoration – recasting with concrete or mortar
    • 4.4 – Structural strengthening – adding mortar or concrete
    • 5.3 – Increasing physical resistance – adding mortar or concrete
    • 6.3 – Resistance to chemicals – adding mortar or concrete
    • 7.1 – Preserving or restoring passivity – increasing cover with additional mortar or concrete
    • 7.2 – Preserving or restoring passivity
  • Uses include:
    • Concrete repairs to accept foot and vehicular traffic
    • Forming of new pavement areas
    • Re-instatement of deteriorated pavement areas
    • Rapid repairs to roadways & runways
    • Structural support situations



Standards


EN1504-3

Products for structural repair CC Mortar (based on hydraulic cement)

Compressive strength EN 12190 Class R4
Chloride ion content EN 1015-17 ≤ 0.05%
Adhesive bond EN 1542 ≥ 2MPa
Restrained shrinkage / expansion EN 12617-4 ≥ 2MPa
Carbonation resistance EN 13295 Passes
Elastic modulus EN 13412 41.2 GPa
Dangerous substances Complies with 5.4
Reaction to fire Class A1



Typical Tecfast Concrete Properties @ 20°C


(At 20°C and 9% (2.25litres) water addition)

Property Standard Result
Consistency   Flowing concrete
Initial set EN 197-1 15min
Final set EN 197-1 20min
Compressive strength EN 12190

2 hour - 20MPa

1 day - 35MPa

7 day - 45MPa

28 day - 65MPa

Elastic Modulus in compression EN 13412 41.2GPa @ 28 days
Bond strength via pull off EN 1542 2.4 MPa @ 28 days
Set density EN 12390-7 2250-2300 kg/m³
Cl- content EN 1015-17 <0.003%



Instructions For Use


Preparation

Laitance and all loose material including dust, oil and grease should be removed in order to produce a sound substrate. The work area should be pre-wetted taking care to remove any standing water before placing the Tecfast Concrete.

 

Mixing

To achieve the most consistent concrete mix, mechanical mixing using a forced action mixer such as the Creteangle is recommended. Small mixes may be made using a heavy duty slow speed high torque drill and Mortar Stirrer.

Each 25kg bag of Tecfast Concrete requires 2.25 litres of water to give a medium workability concrete consistency. Excess water should not be added. Once setting of the concrete has commenced, further mixing should not be used to re-work the mix.

The concrete should be placed within approximately 15 minutes of mixing. The working time may be extended in cold ambient conditions and may be slightly shortened in hot ambient conditions. For cold weather working warm mixing water at up to 30°C may be used.

Part bag mixing should not be undertaken.

 

Placing

Mixed Tecfast Concrete should be placed onto the dampened prepared surface as soon as mixing is complete. Once placed fully compact the concrete to obtain maximum strength development. The bed thickness applied in a single application should be between 20mm to 650mm.

The placed concrete will have hardened sufficiently to carry out further work within some 20 minutes depending on the surrounding ambient conditions.

 

Curing

No special curing is required at temperatures between 5°C and 35°C. For placing at temperatures outside this range contact our technical team on 0113 2455450 (option 2) or send a message to [email protected].

At early ages do not allow placed concrete to rapidly dry and protect from rain and frost.



Product Details
9665-966509

Data sheet

Manufacturer
Sika
Interior / Exterior Use
Exterior Use
For Use On
Concrete
Pack Size
25kg
Pack Size
25KG
Coverage
Each 25kg bag approximately 11.5 litres
Size
25kg
UN Number
N/A
Base Type
Cement-Based
Suitable For Use On
Concrete
Manufacturer
Sika
Components
1K
Usages
Concrete Repair
Product Usage Type
Repair Concrete
Product Range
Parex
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)
questions Karl on 2024-04-16 16:17:05
Question: 

Can you tell me what the anti slip grade is of this product

Answer from Rawlins’ Technical Team:

There is no anti-slip variant of this product.

Sika Parex Tecfast Concrete has been used successfully for many years for horizontal applications where it receives both pedestrian and vehicular traffic and no issues have been reported with slip resistance.

When the product has stiffened, it is possible to create a surface texture (e.g. brush finish) or to blind with kiln dried quartz sand for added slip resistance.

IMPORTANT SHIPPING & DELIVERY INFORMATION

Sika Parex Tecfast Concrete is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT