Intumescent material encased within a waterproof glass cloth bag. They are designed to create a temporary or permanent fire seal around all types of services to maintain continuity of fire performance of compartment walls. They are an ideal solution for applications where services are required to be changed or replaced on a regular basis.
Easy to install, they are simply packed tightly in between penetrating services and the wall.
- Provides up to 2 hours* (EI 120) fire protection for differing services
- Designed to provide fire stopping to metal services, plastic conduits and cables passing through fire resisting compartment walls
Quick Links - Click To Jump To Section:
Features & Benefits
- Under fire conditions, Intumescent Pillows CE expand several times their original volume to form an effective seal around service penetrations
- Intumescent Pillows CE are suitable for use with:
- Metal pipework
- Plastic conduits
- Cable trays/ladders
- Easy to install
- Easy to remove and reinstate when changing services
- Dry system
- Provide up to 2 hours* fire rating where services pass through fire-rated walls
- CE marked to EAD 350454-00-1104
*Subject to application.
Installation
Please see Product Data Sheet and Installation Guide for detailed installation instructions.
Installation in Walls
- Push the first Intumescent Pillow CE into the hole to be filled, so that the longest dimension (330mm long) spans across the wall with 75mm projection from either face
- Pack the hole tightly with additional Intumescent Pillows CE, staggering the joints, until it is tightly packed
- For wall penetrations, the pillows are normally self supporting, but for large openings with few penetrations, you may require a steel retaining mesh for support on both sides of the penetration
- Smaller pillows are used as appropriate to fill smaller gaps
Installation of Service Penetrations
- The total amount of cross sections of services should not exceed 60% of the penetration area
- The minimum permitted separation between adjacent seals/apertures is 200mm
- Pipes must be installed singular, cables require no minimum separation
- Services in walls shall be supported via steel angles/hangars/channels a maximum 250mm (BS EN 1366-3:2009) or a maximum 500mm (BS 476:Part 20:1987) from the face of the separating element
- Pipes must be perpendicular to the seal surface. Plastic conduits or trunking should be cut short by at least 100mm either side of pillow seal
Coverage
Pillow Size (mm) | Approximate Number |
---|---|
330 x 200 x 45 | 113 per m2 opening |
330 x 200 x 25 | 180 per m2 opening |
330 x 50 x 20 | As required to fill small voids |
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Data sheet
- Manufacturer
- Rockwool
- For Use By
- Professional Use
- Interior / Exterior Use
- Interior Use
- For Use On
- Service voids in walls
- Single, Two or Three Pack
- Single
- Pack Size
- 330 x 200 x 45
330 x 200 x 25
330 x 50 x 20 - Suitable For Use On
- Wall Voids
- Manufacturer
- Rockwool
- Product Usage Type
- Fire Pillow
- Fire Rating
- 120 Minutes
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Rockwool Intumescent Pillows CE is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT