Follow us on:

Rockwool Firepro Pipe Collar CE | Up to EI240 Fire Resistance

Rockwool Firepro Pipe Collar CE

294131
ROC9750

A corrosion resistant powder coated steel sleeve, containing a flexible graphite based intumescent liner which is manufactured to suit standard diameter plastic pipework. Under fire conditions, the intumescent material within the collar expands, crushing the pipework and closing the void left by the pipework, preventing the passage of fire.

Tested to the harmonised European Standard EN 1366-3:2009, Firepro Pipe Collar CE provides up to 4 hours* fire stopping in rigid floor constructions and up to 2 hours fire stopping in flexible/rigid wall constructions.

294136 - 55mm, 294142 - 110mm, and 294145 - 160mm are available on 3-5 working days delivery. All other sizes available on 7-10 working days delivery.

Size
£9.53(incl. VAT)
£7.94(ex. VAT)
Quantity
Please choose your colour
Available for Delivery (See Delivery Options Below)

No queries yet, leave the first!
Description

Tested to the harmonised European Standard EN 1366-3:2009, Firepro Pipe Collar CE provides up to 4 hours* fire stopping in rigid floor constructions and up to 2 hours fire stopping in flexible/rigid wall constructions. 

Firepro Pipe Collar CE is slim in design (depth 30mm or 40mm) allowing it to be installed around a service where space is restricted. The product can be installed on flexible wall, rigid wall and rigid floor constructions. When used around plastic combustible pipes, it will form a penetration seal to reinstate the fire resistance performance of the wall or floor construction.

Firepro Pipe Collar CE consists of a corrosion resistant powder coated steel sleeve, containing a flexible graphite based intumescent liner which is manufactured to suit standard diameter plastic pipework. Under fire conditions, the intumescent material within the collar expands, crushing the pipework and closing the void left by the pipework, preventing the passage of fire.

*Subject to application.



Quick Links - Click To Jump To Section:




Features & Benefits


  • Tested to reinstate the fire performance of rigid and flexible walls (minimum 100mm) and rigid floors (minimum 150mm) where combustible plastic pipes penetrate.
  • Fire resistance testing to EN 1366-3 and proven to perform for up to EI 240* in rigid floors and EI 120* in flexible/rigid walls
  • Used to seal standard plastic pipe penetrations 32mm – 250mm diameter. Standard plastic pipes tested are PVC-U, PP, PE. Firepro Pipe Collar CE is supplied in assembled form, without fixings. The collar is wrapped around the pipe at the soffit of a rigid floor or both faces of rigid/flexible walls.
  • Suitable for flexible wall and rigid wall/floor constructions
  • Available to suit plastic pipe sizes ranging from 32mm to 160mm OD and PP pipes up to 250mm OD
  • Tested in conjunction with Firepro Ablative Coated Batt seals
  • The performance of Pipe Collar CE will be limited to the performance of the substrate.
  • Certified by UL and CE marked to EAD 350454-00-1104



Installation


  • Please see Product Data Sheet and Installation Guide for detailed installation instructions.
  • Walls shall be a minimum thickness of 100mm or greater
  • Flexible drywalls/partitions shall comprise a minimum of 2 layers of ‘Type F’ Gypsum board on both faces, with minimum 50mm studs
  • Solid block, masonry and concrete walls shall have a minimum density of 780kg/m3 and a minimum thickness of 100mm. Aerated concrete block shall have a minimum density of 600kg/m3
  • Fire Stopping seals at maximum 1200mm high x 730mm wide consisting of a double layer of Ablative Coated Batt seal 2 x 50mm or 2 x 60mm
  • All walls shall have at least the same fire resistance as that required of the sealing system
  • Services penetrating the division shall be suitably supported via steel angles, hangers or channels, no further than 400mm from the surface of the sealing system on both faces
  • Multiple apertures must be separated by a minimum of 200mm in drywalls and concrete/masonry constructions
  • Check services to be treated are within scope of test data
  • All services and apertures need to be thoroughly clean and clear of dust and loose particles
  • Temperature to be 5°C or above at time of installation
  • Gaps of up to 10mm wide around the service within the substrate can be filled with a minimum 5mm deep Firepro Acoustic Intumescent Sealant
  • In rigid walls, for gaps greater than 10mm wide, Rockwool Firestop Compound can be used
  • Fixing straps on the Pipe Collar CE are opened up and the collar is simply fitted around the plastic pipe with the fixing tabs closest to the face of the wall
  • Lock the collar around the pipe by closing the fixing strap. The collar is pushed flush to the surface of the wall
  • The collar is then securely fastened to the substrate by means of fire rated fixings to suit the substrate and installed through the fixing tabs. Steel pig tail screws minimum 80mm are utilised to secure the collar through to the Ablative Coated Batt
  • Repeat for the other side of the wall if required



IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.



Product Details
9750-969628

Data sheet

Manufacturer
Rockwool
For Use By
Professional Use
Interior / Exterior Use
Interior & Exterior
Single, Two or Three Pack
Single
Pack Size
40-250mm diameter
Max. Application Temperature
40°C
Min. Application Temperature
-5°C
Manufacturer
Rockwool
Product Usage Type
Fire Collar
Product Range
Firepro
Fire Rating
240 Minutes
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions

Question about the product

* Required fields
(read)

Be the first to ask a question about this product!

IMPORTANT SHIPPING & DELIVERY INFORMATION

Rockwool Firepro Pipe Collar CE is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

All delivery costs below are excluding VAT


You might also like
Rockwool Firestop Compound | For Cable, Pipe, Duct Penetrations

Rockwool Firestop Compound

Specially formulated gypsum-based compound, which is mixed with water to be trowelled or poured around service penetrations. As part of the comprehensive Firepro range of fire protection products, Rockwool Firestop Compound is used to provide a fire resisting seal around service penetrations in fire rated walls and floors. Provides up to 6...

Price £35.53 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery
Rockwool Acoustic Intumescent Sealant | Up to 4 Hours Fire Protection

Rockwool Acoustic Intumescent Sealant

High specification, one part water based acrylic sealant. Acoustic Intumescent Sealant is designed for use in the installation of Rockwool Ablative Coated Batt, sealing linear joints and some individual service penetrations passing through various substrates. Up to 4 hours* fire protection Used to reinstate the fire resistance of wall and...

Price £3.11 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery
Rockwool 50mm Ablative Coated Batt | Up To 2 Hours Fire Protection

Rockwool 50mm Ablative Coated Batt

A high-density stone wool core, pre-coated on both sides with our high-performance ablative coating. Ablative Coated Batt has been comprehensively tested as part of the Rockwool Firepro range of fire protection products, specifically for use in service penetrations, head of wall and other void seals. Provides fire stopping solutions in...

Price £26.56 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery
Rockwool 60mm Ablative Coated Batt | Up To 4 Hours Fire Protection

Rockwool 60mm Ablative Coated Batt

A high-density stone wool core, pre-coated on both sides with our high-performance ablative coating. Ablative Coated Batt has been comprehensively tested as part of the Rockwool Firepro range of fire protection products, specifically for use in service penetrations, head of wall and other void seals. Provides fire stopping solutions in...

Price £31.25 (incl. VAT)
Shop now
Trustpilot
In Stock and Available for Delivery