UltraFloor Level IT Hydra Bond is a semi-rapid, high performance free flowing, single part smoothing underlayment. It incorporates Ecosphere technology which is made with 20% recycled material for improved application and reduced environmental impact. The product’s unique formulation consists of a powdered blend of cements, polymers, graded fillers and additives. UltraFloor Level IT Hydra Bond is suitable over a wide range of subfloors at depths between 2-12mm and up to 30mm over good solid substrates such as concrete.
- Specially formulated with Ecosphere technology - a unique recycled material
- Advanced performance water mix with exceptional flow and ease of application
Quick Links - Click To Jump To Section:
Features & Benefits
- Specially formulated with Ecosphere technology - a unique recycled material
- Ready to receive bonded floor coverings after 4 hours
- Priming not required (See Priming)
- Use over most common subfloors, including old adhesive residues and bitumen
- Moisture tolerant, low odour and protein free
- Designed for underfloor heating
- Extended working time of 45 minutes for optimal usability
- Advanced performance water mix with exceptional flow and ease of application
- Specifically designed for use over a wide variety of subfloors including:
- Concrete, sand & cement
- Calcium sulphate/anhydrite/hemihydrate screeds
- Existing cementitious underlayments
- Damp proof membranes
- Surface electrical radiant heating systems
- Flooring grade plywood
- Rigid steel
- Flooring grade asphalt
- Hard sound bitumen residues
- Cement or thermal backer boards
- Porcelain, ceramic, quarry or terrazzo floors
- Moisture tolerant adhesive residues
- Protein free formulation means it is ideal for use in biologically sensitive areas
- Moisture tolerant formulation makes it suitable for the pre-smoothing of floors prior to the application of surface damp proof membranes (DPM) and moisture vapour suppressants (MVS)
- Excellent adhesion characteristics
- CE Certified
Subfloor Preparation
- All surfaces must be dry and in a sound and stable condition free from contaminants that may prevent adhesion such as dust, oils, grease, surface laitance, water soluble adhesive residues and weak smoothing underlayments etc.
- Smooth dense surfaces can be roughened by mechanical scabbling to enhance the key
- Subfloors should be tested in accordance with BS8203 to ensure a moisture reading of less than 75% RH is achieved. Where this has not been attained or where there is uncertainty that the subfloor design incorporates a Damp Proof Course (DPC) then UltraFloor DPM IT or UltraFloor Suppress IT must be applied (see relevant UltraFloor product technical datasheet)
- UltraFloor recommend consultation with subfloor preparation equipment suppliers to ensure correct equipment for the substrates is selected
- All substrates must be at a minimum temperature of 5°C before, during and after application of the primer to ensure film forming and bonding is achieved
Priming
Absorbent Subfloors (concrete, sand & cement, plywood etc): Priming is not required for the purpose of adhesion.
NOTE: To ensure a pinhole free surface is attained priming can be carried out using UltraFloor Prime IT Multi-surface Primer (MSP), where this is not important such as applications of textiles or loose lay laminate flooring, priming may be omitted. Subfloors must be sound, stable, free from dust, grease and all debris. Any remaining residues should be firmly bonded, hard and not soluble to water. Specific priming requirements are needed for calcium sulphate/anhydrite/hemihydrate screeds (see Substrate section - Calcium Sulphate/Anhydrite/Hemihydrate Screeds).
Non-absorbent Subfloors (epoxy resin damp proof membranes, moisture tolerant adhesive residues, flooring grade asphalt, porcelain, ceramic, quarry and terrazzo floors, steel mezzanine decks, access panels etc): Priming is not required for the purpose of adhesion, it is also not required with applications to UltraFloor DPM IT or UltraFloor Suppress IT as long as UltraFloor Level IT Hydra Bond is applied within 12 hours of application and it is trafficable.
Substrates
Calcium Sulphate/Anhydrite/Hemihydrate Screeds: Mechanically remove any laitance and provide a sound, clean, dry and dust-free surface. The relative humidity within the subfloor must read below 75% RH prior to the application of a barrier primer (damp proof membranes and moisture vapour suppressants are not recommended). These types of screeds often incorporate warm water underfloor heating systems (see relevant manufacturers’ technical datasheet) which can be used, along with dehumidifiers, to speed up the drying process. Manufacturers normally suggest this can be conducted after 7 days minimum curing. Apply UltraFloor Prime IT Multi-surface Primer (MSP) diluted 3:1 with clean water and allow to fully dry overnight. Apply a second coat diluted 1:1 with clean water allowing it to dry to a pink film (usually 1-2 hours).
Plywood/Tile Backer Board: Plywood must be of flooring grade and mechanically fixed to a sound strong base. UltraFloor Level it Hydra Bond is only recommended for use with plywood of 15mm thickness and greater. Tile backer boards of 6mm thickness. Plywood must be sealed on the underside and along all edges to ensure moisture absorption from beneath is kept minimal. For thinner flooring grade plywood subfloors contact UltraFloor’s technical department. Plywood and tile backer board absorbency differs depending on the nature of the surface. Normally a diluted coat of UltraFloor Prime IT Multi-surface Primer (MSP) (3:1 with clean water) is recommended. For dense surfaces of very low absorbency apply UltraFloor Prime IT Multi-surface Primer (MSP) neat in a thin uniform coating. Allow primer coats to fully dry.
Flooring Grade Asphalt: New asphalt must be left for a minimum of 7 days and degreased to remove surface bloom. Existing asphalt should be assessed for cracks. If cracks are present they need to be repaired to give a continuous strong subfloor. The use of epoxy resins bulked out with sand is normally sufficient.
Non-flexing Steel Floors (e.g. mezzanine decks): Mechanically abrade using a suitable mechanical machine (STG or shot blast)) or a wire brush to give an abraded shiny corrosion free surface and remove all excess traces of metal. Patching prior to Plywood Overlays: Sound stable subfloors including T and G floor boards that are to be overlayed with flooring grade plywood may first be smoothed or patch filled with UltraFloor Level IT Hydra Bond.
Pre-smoothing of Subfloors: Where there is an absence of a DPC pre-smoothing can be carried out provided there is no risk of hydrostatic pressure and all previous materials have been removed to leave the cementitious base. If in any doubt, please apply UltraFloor DPM IT (see relevant UltraFloor product technical datasheet) directly to the original subfloor. Pre-smoothing is not suitable over old adhesive residues.
Surface DPM and MVS: hese are considered as non-absorbent substrates. Applications should be carried out within 12 hours of UltraFloor DPM IT and/or UltraFloor Suppress IT application (see relevant UltraFloor product technical datasheets).
Radiant Electrical Underfloor Heating Systems: UltraFloor Level IT Hydra Bond can also be used over electrical UFH systems where the cables are fixed to a sound strong mechanical fixed cement faced backer board. Apply UltraFloor Prime IT Multi-surface Primer (MSP) diluted 3:1 with clean water and allow to dry fully (usually 1-2 hours). It may also be used where electrical UFH is used over cementitious or calcium sulphate subfloors. Priming should be as per the substrate. In all cases UltraFloor Level IT Hydra Bond must be applied at a thickness of 5mm above the cables for resilient, textile and timber applications and a minimum of 3mm for application of stone, ceramic or porcelain products.
Warm Water Underfloor Heating Systems (UFH): Systems must have been fully commissioned and brought up to their maximum temperature, and ideally switched off 48 hours before application. In the absence of other heat sources, the UFH may be set to ‘cutback’ position to achieve an air temperature of 15°C. Any expansion or movement joints must be carried through to the floor covering surface.
Please note: The installation of underfloor heating systems needs to sound, solid and secure to ensure no movement. Please refer to manufacturer’s installation guidance.
Vinyl Tiles: Not all vinyl tile flooring is suitable to be levelled/tiled over. Cushioned or flexible vinyl tiles should not be overlaid and must be removed along with the adhesive residue. Hard vinyl tiles should be lightly abraded and then primed with UltraFloor Prime IT Multi-surface Primer (MSP neat)
Application
- Pour 4 litres of cold clean water into an oversized bucket (20 litres or more capacity)
- Gradually add the powder whilst continually mixing using an electric drill fitted with a power whisk, suitable for use with cement materials
- After completely adding the powder, continue mixing for a further 2 minutes, keeping the whisk below the surface of the product to minimise air entrainment, until a lump free creamy material is attained
- Do not add further water
- Level IT Hydra Bond can be pump or trowel applied
- Pour onto the floor and spread with a smooth edge steel trowel
- UltraFloor Level IT Hydra Bond has exceptional flow characteristics, a spiked roller may be used to further improve the finish particularly between adjacent units of product
- Only spike roll whilst the product is still in its fluid state, typically up to 20 minutes after application
- Tools should be thoroughly cleaned in water to remove excess materials immediately after use
- All curing and drying times are based on good site conditions i.e. an air temperature of 20°C, air humidity of 65% RH and good ventilation
- Sites that are cold, humid or damp or in areas where the airflow is poor, will prolong drying and curing times, so allowances should be made accordingly
- Applications to non-absorbent substrates and at thicker application depths will take longer to dry
- Level IT Hydra Bond is ready to receive light foot trafficking normally after 2-2.5 hours, based on 3mm thick application
- Floor coverings can be bonded in as little as 4 hours
NOTE: Avoid strong drafts and direct sunlight during curing.
Coverage Rates:
Applied Thickness | Coverage per Unit | Consumption Per 100m² Area |
---|---|---|
2-3mm | 5m² | 20 units |
5mm | 2.4m² | 42 units |
12mm | 1m² | 100 units |
30mm | 0.4m² | 250 units |
Data sheet
- Manufacturer
- Instarmac
- Interior / Exterior Use
- Interior Use
- For Use On
- Subfloors
- Application Method
- Pump, trowel
- Single, Two or Three Pack
- Single
- Pack Size
- 20KG
- Pot Life (at 20°C)
- 45 minutes
- Coverage
- See Coverage Rates
- Compressive Strength (at 20°C)
- 1 Day: 10N/mm²
7 Days: 12N/mm²
28 Days: 15N/mm² - Flexural Strength (at 20°C)
- 1 Day: 2N/mm²
7 Days: 3N/mm²
28 Days: 5N/mm² - Shelf Life (from date of manufacture)
- 8 months
- Layer Thickness
- 2-30mm
- Drying time
- Walk on hardness time at 20°C 2.5 hours
- Walk-on Time
- 2-2.5 hours
- Dry for Topcoat
- 4 hours (3mm application)
- Base Type
- Cement Based
- Suitable For Use On
- Anhydrite Screeds
- Suitable For Use On
- Ceramic
- Suitable For Use On
- Terrazzo Floors
- Suitable For Use On
- Calcium Sulphate Screeds
- Suitable For Use On
- Hemihydrate Screeds
- Suitable For Use On
- Existing Cementitious Underlayments
- Suitable For Use On
- Concrete
- Suitable For Use On
- Damp Proof Membranes
- Suitable For Use On
- Steel
- Suitable For Use On
- Surface Electrical Radiant Heating Systems
- Suitable For Use On
- Flooring Grade Plywood
- Suitable For Use On
- Cement
- Suitable For Use On
- Quarry Floors
- Suitable For Use On
- Porcelain
- Suitable For Use On
- Hard Sound Bitumen Residues
- Suitable For Use On
- Plywood
- Suitable For Use On
- Cement Backer Boards
- Suitable For Use On
- Sand and Cement
- Suitable For Use On
- Thermal Backer Boards
- Suitable For Use On
- Rigid Steel
- Suitable For Use On
- Ceramic Floors
- Suitable For Use On
- Flooring Grade Asphalt
- Suitable For Use On
- Moisture Tolerant Adhesive Residues
- Suitable For Use On
- Porcelain Floors
- Application Method
- Trowel
- Application Method
- Pump
- Usages
- Self Levelling
- Usages
- Suitable for underfloor heating
- Product Usage Type
- Screed
- Product Range
- Ultrafloor
- Product Attributes
- Self Levelling
- Product Attributes
- Suitable For Underfloor Heating
Questions
Question about the product
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
Instarmac UltraFloor Level It Hydra Bond is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT
Instarmac UltraFloor Prime It Multi-Surface Primer
UltraFloor Prime IT Multi-surface Primer (MSP) is a moisture tolerant, water based polymer primer, sealer and bonding aid suitable for porous and non-porous substrates. UltraFloor Prime IT MSP is a pink liquid and dries to give a pink film. Enhances adhesion and reduces pinholing Can also be used as a curing agent for cementitious based...
Instarmac UltraFloor DPM It
UltraFloor DPM IT rapid curing primer membrane is a two component, solvent free epoxy resin system for use as a surface damp proof membrane (DPM) and as a screed bonding aid (primer) for industrial flooring applications. It is supplied in a twin pack dual chamber to enable ease of transport and mixing. The product performs by a reaction...
Instarmac UltraFloor Suppress It
UltraFloor Suppress IT is a single component, two-coat rapid drying moisture suppressant primer membrane. It has a water based, solvent free formulation and is designed to suppress residual construction moisture – up to 95% relative humidity in cementitious subfloors (when tested with a properly calibrated surface hygrometer in accordance with...